Type | Suitable power(kW) | Output | Input | Brake unit | Cooling method | ||||
---|---|---|---|---|---|---|---|---|---|
Voltage(V) | Rated current(A) | Overload capacity | Rated power(V) | Range of voltage(V) | Rated current(A) | ||||
CV100-4T-0075G | 7.5 | 3-phase 0~rated input voltage | 17.0 | 150% 1 Minute; 180% 10 Seconds; 10 minutes interval(inverse time limit speciality) | 3-phase 380V~440V AC; 50Hz/60Hz | 320V~460V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% | 20.5 | Built-in | Cooling by fan |
CV100-4T-0055G | 5.5 | 3-phase 0~rated input voltage | 13.0 | 150% 1 Minute; 180% 10 Seconds; 10 minutes interval(inverse time limit speciality) | 3-phase 380V~440V AC; 50Hz/60Hz | 320V~460V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% | 14.5 | Built-in | Cooling by fan |
CV100-4T-0037G | 3.7 | 3-phase 0~rated input voltage | 8.8 | 150% 1 Minute; 180% 10 Seconds; 10 minutes interval(inverse time limit speciality) | 3-phase 380V~440V AC; 50Hz/60Hz | 320V~460V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% | 10.5 | Built-in | Cooling by fan |
CV100-4T-0022G | 2.2 | 3-phase 0~rated input voltage | 5.5 | 150% 1 Minute; 180% 10 Seconds; 10 minutes interval(inverse time limit speciality) | 3-phase 380V~440V AC; 50Hz/60Hz | 320V~460V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% | 5.8 | Built-in | Cooling by fan |
CV100-4T-0015G | 1.5 | 3-phase 0~rated input voltage | 3.7 | 150% 1 Minute; 180% 10 Seconds; 10 minutes interval(inverse time limit speciality) | 3-phase 380V~440V AC; 50Hz/60Hz | 320V~460V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% | 5.0 | Built-in | Cooling by fan |
CV100-4T-0007G | 0.75 | 3-phase 0~rated input voltage | 2.3 | 150% 1 Minute; 180% 10 Seconds; 10 minutes interval(inverse time limit speciality) | 3-phase 380V~440V AC; 50Hz/60Hz | 320V~460V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% | 3.4 | Built-in | Cooling by fan |
CV100-2S-0022G | 2.2 | 3-phase 0~rated input voltage | 10.0 | 150% 1 Minute; 180% 10 Seconds; 10 minutes interval(inverse time limit speciality) | single phase 200V~240V AC; 50Hz/60Hz | 180V~260V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% | 23.0 | Built-in | Cooling by fan |
CV100-2S-0015G | 1.5 | 3-phase 0~rated input voltage | 7.5 | 150% 1 Minute; 180% 10 Seconds; 10 minutes interval(inverse time limit speciality) | single phase 200V~240V AC; 50Hz/60Hz | 180V~260V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% | 14.0 | Built-in | Cooling by fan |
CV100-2S-0007G | 0.75 | 3-phase 0~rated input voltage | 4.0 | 150% 1 Minute; 180% 10 Seconds; 10 minutes interval(inverse time limit speciality) | single phase 200V~240V AC; 50Hz/60Hz | 180V~260V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% | 8.2 | Built-in | Cooling by fan |
CV100-2S-0004G | 0.4 | 3-phase 0~rated input voltage | 2.5 | 150% 1 Minute; 180% 10 Seconds; 10 minutes interval(inverse time limit speciality) | single phase 200V~240V AC; 50Hz/60Hz | 180V~260V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% | 5.3 | Built-in | Cooling by fan |
CV100-2S-0002G | 0.2 | 3-phase 0~rated input voltage | 1.3 | 150% 1 Minute; 180% 10 Seconds; 10 minutes interval(inverse time limit speciality) | single phase 200V~240V AC; 50Hz/60Hz | 180V~260V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% | 2.3 | Built-in | Cooling by fan |